RadPair

Cross-Modal Alignment and Unified Representation Methods
for Medical Imaging and Clinical Text Data

Machine Intelligence Lab, Sichuan University

The question

On a controlled 15,000-pair CheXpert Plus subset, can a lightweight ResNet-50 + BioClinicalBERT dual encoder learn useful chest X-ray–report alignment without training a new foundation model?

15,000
Study pairs
3,189
Sealed test pairs
256-D
Shared embeddings
1,016,320
Trainable params (PEFT)

Abstract

Chest X-ray–report alignment is difficult because reports are long, frequently negative, and partly templated, so a contrastive model can retrieve a plausible report without aligning the image to the specific study. RadPair studies whether that gap can be narrowed cheaply. It evaluates bidirectional retrieval, image–text matching, 14-label disease classification, label uncertainty handling, and missing-modality behavior under one patient-level protocol on a controlled 15,000-pair CheXpert Plus subset, using a ResNet-50 image branch and a BioClinicalBERT text branch trained with symmetric InfoNCE at a fixed temperature of 0.07.

The comparison spans three adaptation recipes: frozen projections, LoRA-based parameter-efficient fine-tuning of the text encoder, and a partially end-to-end configuration, all sharing the same split, preprocessing, loss, batch size, epoch budget, and validation-based early stopping. Training and model selection use validation only; the sealed 3,189-pair test set is evaluated once. Retrieval is reported against exact-gallery chance and a five-run shuffled-pair control, and disease metrics use a predeclared U-Ignore mask for uncertain CheXpert labels.

Parameter-efficient fine-tuning is the shared default: it reaches validation image→text Recall@1 of 0.01910 against 0.01054 for frozen projections and 0.02503 for partial end-to-end training, with roughly 1.7% of the end-to-end trainable parameters and a far smaller train–validation gap. On the sealed test, the selected encoder reaches 0.00878 image→text and 0.01035 text→image Recall@1, about 28× and 33× chance; the 14-label disease head reaches 0.7117 macro-AUROC from image embeddings and 0.8589 from text embeddings; and the image–text matching head reaches 0.6942 AUROC. Absolute retrieval numbers stay low, which is the expected behavior for a controlled subset scored against an exact-study gallery. These results support a documented research pipeline and a reusable shared embedding, not diagnostic deployment.

Research Design

Scientific motivation

Radiology reports are long, mostly negative, and partially templated. A model can therefore score a high-quality-looking report as a good match for almost any study. RadPair addresses this with a deliberately narrow, checkable design:

  • Controlled scale: 15,000 frontal study pairs rather than an opaque large-scale run.
  • Patient-level separation: no patient is shared across train, validation, or test.
  • Honest retrieval baselines: exact-gallery chance and shuffled-pair checks accompany every Recall@K.
  • Declared uncertainty policy: uncertain CheXpert labels are masked with U-Ignore before test use.
  • Adaptation spectrum: frozen, parameter-efficient, and partially end-to-end recipes are compared.
  • Reusable output: normalized 256-dimensional image and text embeddings behind a documented API.
Dual encoder architecture: ResNet-50 image branch and BioClinicalBERT text branch project to 256 dimensions, are L2 normalized, and feed symmetric InfoNCE, an image-text matching head, a 14-label disease head, and the embedding API.
Figure 1. Dual encoder architecture. Both branches project into one L2-normalized 256-dimensional space.
Experimental protocol flowchart: licensed CheXpert Plus dump, controlled 15,000-pair subset, patient-level 70/10/20 split, validation-only contrastive alignment, PEFT encoder selection, disease and image-text matching heads, missing-modality validation, one-shot sealed test, then metrics, logs, checkpoints, and the embedding API.
Figure 2. Experimental protocol. Selection happens on validation; the sealed test is touched once, at the end.

Data

SourceCheXpert Plus, accessed under its license
Controlled subset15,000 frontal study pairs
Unique patients4,965
SplitPatient-level 70 / 10 / 20
Train / validation / test10,293 / 1,518 / 3,189 pairs
Seed42
Text fieldsFindings + Impression
Labels14 CheXbert observations
Uncertainty policyU-Ignore
Image preprocessingChambon Appendix A → 8-bit JPG → 224×224 RGB

Adaptation groups

Group Trainable components Trainable parameters Role
G_frozen Image/text projections only 721,408 Minimal adaptation baseline
PEFT ResNet frozen; LoRA on BioClinicalBERT query/value; projections 1,016,320 Efficiency/generalization trade-off, shared default
Partial e2e ResNet layer 4; BioClinicalBERT last six layers; projections 58,803,968 Stronger adaptation and overfitting probe

All groups share the same split, preprocessing, loss, batch size, maximum epochs, and validation-based early stopping. The partial end-to-end group is not full backbone fine-tuning.

Results

Validation: three-way contrastive comparison

Chance Recall@1 on the 1,518-pair validation gallery is 1 / 1,518 ≈ 0.000659.

Group Best epoch Val i→t R@1 Val t→i R@1 Shuffle i→t R@1 Train@best i→t Interpretation
G_frozen 7 0.01054 0.00922 0.00092 0.0586 Stable but weak alignment
PEFT 11 0.01910 0.01910 0.00079 0.1738 Stronger signal with modest overfitting
Partial e2e 10 0.02503 0.02503 0.00066 0.7559 Best validation score, largest train–validation gap

Train@best Recall is measured on a seeded 512-pair train monitor, not the full training gallery.

Validation Recall at 1 by adaptation group: G_frozen 0.01054 image-to-text and 0.00922 text-to-image with 721,408 trainable parameters; PEFT 0.01910 in both directions with 1,016,320 parameters; partial end-to-end 0.02503 in both directions with 58,803,968 parameters. Chance is 0.000659.
Figure 3. Validation Recall@1 by adaptation group, with trainable-parameter cost and the chance line.
Train versus validation Recall at 1 at each run's best epoch: G_frozen train 0.0586 versus validation 0.01054; PEFT train 0.1738 versus validation 0.01910; partial end-to-end train 0.7559 versus validation 0.02503, showing memorization.
Figure 4. Train–validation gap at the best epoch. The partial end-to-end run reaches the best validation score while memorizing the training split.

Why PEFT is the default. It provides most of the practical alignment gain with roughly 1.7% of the trainable parameters in the partial end-to-end recipe and a smaller train–validation gap. It is not selected solely because it has the highest validation Recall@1.

Held-out results

The sealed test contains 3,189 pairs. Chance Recall@1 is 0.000314; the mean shuffled image→text Recall@1 is 0.000439. The encoder is plus_g_peft_001 with the disease and ITM heads attached.

Sealed test retrieval: image to text Recall at 1, 5, 10 equals 0.00878, 0.03857, 0.05864; text to image equals 0.01035, 0.04265, 0.07244. Chance Recall at 1 is 0.000314.
Figure 5. Sealed-test bidirectional retrieval, roughly 28× and 33× chance at Recall@1.
TaskMetricValue
Image→text retrievalR@10.00878
Image→text retrievalR@50.03857
Image→text retrievalR@100.05864
Text→image retrievalR@10.01035
Text→image retrievalR@50.04265
Text→image retrievalR@100.07244
Disease, image-onlymacro-AUROC0.71172
Disease, image-onlymacro-F10.20448
Disease, text-onlymacro-AUROC0.85892
Disease, text-onlymacro-F10.48181
Image–text matchingAUROC0.69425
Image–text matchingAccuracy0.64189
Disease head and matching head on the sealed test: disease image-only macro-AUROC 0.7117 and macro-F1 0.2045; disease text-only macro-AUROC 0.8589 and macro-F1 0.4818; image-text matching AUROC 0.6942 and accuracy 0.6419 over 6,378 pairs.
Figure 6. Auxiliary heads on the sealed test. Text-only disease performance is higher because the 14 labels are derived from report text.

Ablations

AblationComparisonValidation result
A2: adaptation on/off G_frozen versus PEFT, same Findings + Impression recipe i→t R@1 0.01054 → 0.01910
A1: text section Findings + Impression versus Findings-only Findings-only i→t R@1 0.03297 on 364 validation pairs
Two ablations. Adaptation off gives validation image-to-text Recall at 1 of 0.01054 and adaptation on gives 0.01910. Findings plus Impression gives 0.01910 over 1,518 validation pairs against 0.03297 for Findings-only over 364 validation pairs.
Figure 7. Ablations A2 and A1. The findings-only run uses a smaller gallery and a different sample availability rule.

The findings-only ablation uses a smaller validation gallery and a different sample availability rule, so its absolute Recall@1 is not directly comparable with the main validation table. It is approximately 12× its own chance level of 0.00275.

Evaluation safeguards

  • Training and model selection use validation only.
  • Test rows are refused by the standard data loader unless the evaluation script explicitly enables test access.
  • Retrieval is compared with exact-gallery chance and a five-run shuffled-pair control.
  • Disease metrics use the predeclared U-Ignore mask.
  • After validation-only selection, the held-out test is evaluated once with the selected PEFT encoder plus disease and ITM heads.
  • Those test metrics are not used for tuning.

Interpretation

  • Retrieval is well above chance and the shuffled control, but absolute Recall@1 remains low. This is expected for a controlled 15,000-pair subset and an exact-study gallery.
  • Partial end-to-end training achieves the best validation retrieval score but shows clear memorization risk.
  • Text-only disease performance is much higher because the 14 labels are derived from report text; this is not evidence that text embeddings are clinically superior to image embeddings.
  • The results support a documented research pipeline and a usable shared embedding, not diagnostic deployment.

Embedding API

The main reusable output is a shared embedding space. Callers own preprocessing: image callers supply ImageNet-normalized (B, 3, 224, 224) tensors, text callers supply token IDs and attention masks. Both functions return L2-normalized 256-dimensional embeddings, so image and text vectors are directly comparable by cosine similarity.

Schematic of the embedding API contract: image or text inputs enter embed_image or embed_text and leave as L2-normalized 256-dimensional vectors that are directly comparable by cosine similarity.
Figure 8. Interface contract for the shared embedding space.
from transformers import AutoTokenizer
from src.api import load_dual_encoder, embed_image, embed_text

device = "cuda:0"
model = load_dual_encoder(device=device)
tokenizer = AutoTokenizer.from_pretrained(
    "models/Bio_ClinicalBERT", local_files_only=True
)

# Image caller supplies ImageNet-normalized (B, 3, 224, 224) tensors.
image_embedding = embed_image(model, pixel_values)

# Text caller supplies token IDs and attention masks.
text_embedding = embed_text(
    model,
    batch["input_ids"].to(device),
    batch["attention_mask"].to(device),
)

See docs/embed_api.md in the repository for checkpoint behavior, preprocessing ownership, and PEFT loading details.

Reproduce

Prerequisites

  • A licensed CheXpert Plus download, including the source CSV, DICOM files, and CheXbert label file.
  • The local, non-public chexpert_plus_subset/manifest.csv created for this study.
  • One CUDA-capable GPU.
  • Python 3.11 and a virtual environment.
  • The pinned PyTorch and torchvision wheels target CUDA 12.8; install matching wheels for your platform before pip install -r requirements.txt.
git clone https://github.com/codewith-rafi/radpair.git
cd radpair
python -m venv .venv
source .venv/bin/activate

# Install the PyTorch wheels for your platform first, then:
pip install -r requirements.txt
huggingface-cli download emilyalsentzer/Bio_ClinicalBERT \
  --local-dir models/Bio_ClinicalBERT

export RADPAIR_ROOT="$(pwd)"
export CHEXPERT_PLUS_ROOT=/path/to/chexpert_plus

Data build

python scripts/write_plus_split_manifest.py \
  --split train --out data/processed/plus_train_manifest.csv
python scripts/write_plus_split_manifest.py \
  --split val --out data/processed/plus_val_manifest.csv

python scripts/join_plus_chexbert_and_stats.py
python scripts/build_plus_test_manifest.py

# Cache train/validation images.
python scripts/cache_plus_chambon_jpg.py

# Cache held-out test images through the same preprocessing path.
python scripts/cache_plus_chambon_jpg.py \
  --train_manifest data/processed/plus_test_manifest.csv \
  --val_manifest data/processed/plus_test_manifest.csv

Training and evaluation

export CUDA_VISIBLE_DEVICES=0

# Three comparison groups.
python scripts/train_plus_g1.py --config configs/plus_g1.yaml
python scripts/train_plus_g_peft.py --config configs/plus_g_peft.yaml
python scripts/train_plus_g_e2e.py --config configs/plus_g_e2e.yaml

# Auxiliary heads on frozen PEFT embeddings.
python scripts/train_plus_disease.py --config configs/plus_disease.yaml
python scripts/train_plus_itm.py --config configs/plus_itm.yaml

# Validation analyses.
python scripts/eval_plus_missing_modality.py \
  --config configs/plus_missing_modality.yaml

# One-shot held-out evaluation after all choices are fixed.
python scripts/eval_plus_sealed_test.py \
  --config configs/plus_sealed_test.yaml

To regenerate the reported tables without retraining, place locally stored checkpoints under the corresponding experiment directories and verify their SHA256 hashes before use.

Repository Map

src/models/Dual encoder, disease head, and ITM head
src/losses/Symmetric InfoNCE and masked BCE
src/data/Manifest loading, U-Ignore parsing, and preprocessing
src/eval/Recall@K implementation
src/api/Reusable embedding interface
scripts/Data, training, and evaluation entry points
configs/Run configurations
experiments/Metrics, logs, configuration snapshots, and consolidated result tables
chexpert_plus_subset/Public-safe aggregate metadata only
docs/API documentation and visual-asset guidance

Data governance

  • Obtain CheXpert Plus directly from Stanford AIMI and comply with its access terms.
  • Set CHEXPERT_PLUS_ROOT to the licensed local dump.
  • Never commit patient-level images, DICOM files, report-text CSVs, manifests, or derived patient identifiers.
  • The repository intentionally ships only aggregate metadata and experiment results: no patient images, report text, manifests, or model binaries.

BibTeX

@misc{RadPair2026,
  title        = {RadPair: Cross-Modal Alignment and Unified Representation Methods for Medical Imaging and Clinical Text Data},
  author       = {Ahmed, Rafi},
  year         = {2026},
  howpublished = {\url{https://codewith-rafi.github.io/radpair/}},
  note         = {Code and experiments: \url{https://github.com/codewith-rafi/radpair}},
  keywords     = {contrastive learning, chest X-ray, radiology report, CheXpert Plus}
}

Cite the software repository and this project page. Patient-level data are never redistributed; the licensed CheXpert Plus dump must be obtained separately.

References

  1. A. Radford et al., “Learning Transferable Visual Models From Natural Language Supervision,” in Proc. ICML, 2021. arXiv:2103.00020
  2. Y. Zhang, H. Jiang, Y. Miura, C. D. Manning, and C. P. Langlotz, “Contrastive Learning of Medical Visual Representations from Paired Images and Text,” in Proc. Machine Learning for Healthcare (MLHC), 2022. arXiv:2010.00747
  3. S.-C. Huang, L. Shen, M. P. Lungren, and S. Yeung, “GLoRIA: A Multimodal Global-Local Representation Learning Framework for Label-efficient Medical Image Recognition,” in Proc. ICCV, 2021.
  4. E. Tiu, E. Talius, P. Patel, C. P. Langlotz, A. Y. Ng, and P. Rajpurkar, “Expert-level detection of pathologies from unannotated chest X-ray images via self-supervised learning,” Nature Biomedical Engineering, vol. 6, pp. 1399–1406, 2022.
  5. P. Chambon, J.-B. Delbrouck, T. Sounack, S.-C. Huang, Z. Chen, M. Varma, S. Q. Truong, C. T. Chuong, and C. P. Langlotz, “CheXpert Plus: Augmenting a Large Chest X-ray Dataset with Text Radiology Reports, Patient Demographics and Additional Image Formats,” 2024. arXiv:2405.19538
  6. J. Irvin et al., “CheXpert: A Large Chest Radiograph Dataset with Uncertainty Labels and Expert Comparison,” in Proc. AAAI, 2019. arXiv:1901.07031
  7. K. You, J. Gu, J. Ham, B. Park, J. Kim, E. K. Hong, W. Baek, and B. Roh, “CXR-CLIP: Toward Large Scale Chest X-ray Language-Image Pre-training,” in Proc. MICCAI, 2023. arXiv:2310.13292
  8. Z. Wang, Z. Wu, D. Agarwal, and J. Sun, “MedCLIP: Contrastive Learning from Unpaired Medical Images and Text,” in Findings of EMNLP, 2022. arXiv:2210.10163